Anchor point for fall protection: requirements and selection

According to EN 795, an anchor point must hold at least 12 kN and should preferably be above you. This is how you choose between a fixed anchor (type A) and an anchor strap, steel cable loop, or removable drilled anchor (type B).

Hef en Hijs Online
· 7 min lezen
Petzl CONNEXION VARIO ankerband, WIRE STROP staalkabelstrop en COEUR PULSE ankerpunt
In dit artikel 8 onderdelen
  1. What requirements must an anchor point meet?
  2. What is the difference between anchor point type A and type B?
  3. What anchor points are there and what can they have?
  4. How do you properly attach an anchor strap?
  5. How strong must concrete be for a drill point?
  6. What does the law say about anchor points?
  7. Frequently asked questions
  8. Read products and more

A fall arrest anchor point must be able to withstand a force of at least 12 kN, as stated in the EN 795 requirements that Petzl repeats in every manual. The anchor point should preferably be above you, so that the fall distance and swing hazard remain small, and in a fall arrest system you always wear an energy absorber that limits the impact force on you to 6 kN. You choose between a fixed anchor point (EN 795 type A, for example, an anchor plate with a bolt in concrete) and a temporary, removable anchor (type B, such as an anchor strap, steel cable loop, or removable drill point). Which one you need depends on the structure to which you attach.

What requirements must an anchor point meet?

The Petzl anchor manuals always mention the same points. An anchor point is good if:

  • the structure and the anchor together hold at least 12 kN (EN 795);
  • it is above your work position, or as high as possible, to limit the fall and swing;
  • only one fall arrest or positioning system is attached to each anchor, unless the manual allows use by two people (CEN/TS 16415);
  • you use an energy absorber that keeps the impact force at 6 kN or less, such as a lanyard with a shock absorber or a fall arrest device;
  • there is enough free space below you so that you do not hit anything in the event of a fall;
  • the connectors meet the standards, for example EN 362 carabiners.

In addition, you need a rescue plan. All Petzl manuals state that you must have a plan and the means to quickly free someone if something goes wrong.

What is the difference between anchor point type A and type B?

Feature Type A (fixed) Type B (temporary)
Example Petzl COEUR anchor plate with BOLT bolt CONNEXION, ANNEAU, WIRE STROP, COEUR PULSE
Attachment Permanently drilled into concrete or rock Around a beam, pipe or girder, or temporarily in a drilled hole
Take to another location No Yes
Where does the strength come from? Quality of concrete or rock and of the installation Strength of the structure around which you attach
Number of users (EN 795) 1 person 1 person; according to CEN/TS 16415 sometimes 2

What anchor points are there and what can they have?

The values below come from the technical manuals. "Max. force on structure" is what the anchor transmits to the structure at most during a fall; the structure must be able to withstand that.

Anchor Standard Max. force on structure Lifespan Note
CONNEXION FIXE / VARIO (anchor strap) EN 795 type B, CEN/TS 16415 (2 people) 22 kN choked, 45 kN looped 10 years Elongation under load: 20 mm (FIXE), up to 800 mm (VARIO 30-200 cm)
ANNEAU (loop strap) EN 566 and EN 795 type B Structure must hold 12 kN 10 years Do not fall into a loop; avoid sharp edges
WIRE STROP (steel cable) EN 795 type B, CEN/TS 16415, EN 354 23 kN choked, 35 kN looped (angle max. 90°) Unlimited Also usable as a line according to EN 354
COEUR PULSE 12 mm (removable drill point) EN 795 type B, CEN/TS 16415, EN 959 Approximately 12 kN Unlimited Drilled hole 12 mm, at least 65 mm deep; permanent deformation from 6 kN
COEUR with BOLT (fixed drill point) EN 795 type A, EN 959 Approximately 12 kN Unlimited Steel only indoors, stainless steel outdoors; do not combine different metals
Petzl drawing of an anchor strap: as an extension to another anchor, single and double looped around a pipe, and choked with the small eye through the large eye

How do you properly attach an anchor strap?

With an anchor strap or steel cable loop, the way of attaching determines how much force the anchor holds. Follow these steps from the manual of the CONNEXION VARIO and the WIRE STROP:

  1. Choose a structure for which it is certain that it can hold 12 kN. If you doubt the strength, do not use the structure as an anchor.
  2. Choose a length that fits. If you loop the strap around the structure, the angle between the two ends must be less than 90°. For a thick beam, a strap that is too short creates too large an angle; then take a longer strap.
  3. Choke the strap (small eye through the large eye) or loop it. Looping is stronger: 45 kN versus 22 kN for the CONNEXION.
  4. Only attach your carabiner to the metal eyes, never to the strap itself. Make sure the carabiner is loaded in the longitudinal direction.
  5. Do not tie a knot in the strap; a knot reduces the strength.
  6. Roll up excess strap with the Velcro, without forming a loop in which you can accidentally hook in.
  7. Stay below the anchor point. If you climb above it, the fall becomes longer.

How strong must concrete be for a drill point?

Petzl tests the COEUR and PULSE anchors in concrete or rock of 50 MPa. Regular concrete has, according to Petzl, a compressive strength of approximately 25 MPa, and in softer material the anchor can hold less. A poorly placed anchor can hold almost nothing. For the COEUR PULSE 12 mm, that means:

  • Drill straight with a metric drill of 12 mm, at least 65 mm deep, with a drill with three or four cutting edges.
  • If you have to push the pin forcefully into the hole, the hole is not round: do not use it.
  • Clean the hole with a brush and a blower; it must be dry and grease-free.
  • After installation, check that the pin is fixed without play. If you doubt, perform an axial pull test of maximum 6 kN.

What does the law say about anchor points?

The Arbobesluit does not prescribe an anchor point, but does prescribe an order. In case of fall hazard, collective measures such as a scaffold, work platform or railing at least 1 meter high come first (article 3.16). Only when that is not possible, do you use personal fall protection with "lanyards of sufficient strength" (article 3.16 paragraph 5). Collective measures have priority (article 7.23). The anchor point is therefore part of the personal system, together with the harness and the lanyard with energy absorber. How you calculate the required height below the anchor, you can read in Free fall space: how much height does a lanyard really need?

Frequently asked questions

How many kN must an anchor point hold?

At least 12 kN according to EN 795. That applies to the whole of the anchor and structure.

Can two people be attached to one anchor point?

According to EN 795, these anchors are for one person. The CONNEXION, WIRE STROP and COEUR PULSE 12 mm also meet CEN/TS 16415 for two people. Follow the manual of your anchor.

Can the anchor point be below my feet?

Petzl advises preferably above your work position. A lower anchor gives a longer fall and more swing; then check in the manual of your lanyard if it is suitable for that and how much free space you need.

How often must an anchor strap be inspected?

Petzl advises at least every 12 months a thorough inspection by a competent person, and after every exceptional event such as a fall. Check the strap and the stitching before every use.

When do you throw away an anchor strap?

After a heavy fall or load, if it does not pass the inspection, if you do not know the usage history or if the lifespan of 10 years has passed.

Read products and more

Sources: Petzl technical manuals CONNEXION FIXE/VARIO (G0007500G), ANNEAU (G0007000G), WIRE STROP (G0015100E), COEUR PULSE/PULSE (G0025700C) and COEUR/BOLT (G0003800F); Arbobesluit articles 3.16 and 7.23 (wetten.overheid.nl, version valid from 01-08-2026). Photos: Petzl. Last checked on November 16, 2026. This article does not replace the user manual of your anchor, harness or lanyard.

Producten uit dit artikel